Colección: Productos

7194 Productos

  • MSA1475A-BU

    MSA1475A-BU

    Introduction Kit-SR500-F, bundle of radar, cable, bracket, Mini AI Appliance, MASS, 4 AI-PTZ licenses. Not for sale.
  • MSA1476

    MSA1476

    On-Site Professional Services, does not include tickets and stay.
  • MSA1479

    MSA1479

    Extra 1 year complete warranty and support coverage for hardware and software. 6,5% MSRP total project price.
  • MSA1481

    MSA1481

    Online Certification Course. Online Technical Certification Course 2-Day online integrator training (price per person)
  • MSA1554A

    MSA1554A

    Magos Industrial grade AI Appliance. AI Appliance for up to 10 PTZ cameras, -25°C to 60°C operating temperature.
  • MSA1588A

    MSA1588A

    Edge AI Appliance for 2 PTZ cameras. Industrial grade, Micro form factor.
  • MSA1588A-BU

    MSA1588A-BU

    Edge AI Appliance Bundle, preloaded with MASS and 2 AI-PTZ licenses.
  • MSERIES-ACC-KIT-5M-OPT1

    MSERIES-ACC-KIT-5M-OPT1

    M SERIES SENSOR ACCESSORY KIT (M12 CONNECTOR), 5M CABLE
  • MSI-FE-CPNL

    Ceiling Panel for Fisheye In-Ceiling
  • MSI-FE-DC-KIT

    Install Accy Kit for Fisheye In-Ceiling
  • MSI-LD-0E

    COVER; Repl; 50% Smoke; Grey; Odr; Mini
  • MSI-LD-1E

    COVER; Repl; Clear; Grey; Odr; Mini
  • MSI-MT-ECLR

    MOUNT,Side Conduit, Odr, Mini
  • MSI-NPTCON-1001

    ADAPTOR, 1-1/2" x 1/2" NPT Male
  • MVXT2D0SAZ00B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 7.5Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SFZ01B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 7.5Hz; cable tail 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SFZ01BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 30Hz; cable tail 4m; sunshield; ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SAZ00B

    MVXT with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; IP H264/AVC version; thermal camera 9mm; 640x512; 7.5Hz; armoured cable 4m (13 ft); sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SFZ01B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 7.5Hz; cable tail 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SFZ01BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 30Hz; cable tail 4m; sunshield; ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2I0SAZ00B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 336x256; 7.5Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2I0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 336x256; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.