Cámaras Pelco

Colección: Cámaras Pelco

1351 Productos

  • PTCC1

    PTCC1

    Pole mount adaptor 80 to 150mm
  • UEAW

    UEAW

    Counter-plate stainless AISI 316L
  • UEAC

    UEAC

    Corner adaptor stainless AISI 316L
  • SURGEPR

    SURGEPR

    Lightning surge protection device
  • ONXMAIRB

    ONXMAIRB

    Ant flange air barrier temp glass NXM36
  • OHEP90INJO

    OHEP90INJO

    Power Injector PoE 90W 1 channel outdoor
  • NXPTZT32EW0Z00CH

    NXPTZT2 120Vac HD30x 25mm VGA 30Hz W3m
  • NXPTZT32BW0Z00CH

    NXPTZT2 120Vac HD30x 25mm QVGA 30Hz W3m
  • NXPTZT32BW0Z00C

    NXPTZT2 120Vac HD30x 25mm QVGA 7.5Hz W3m
  • NXPTZHD32VW0Z00C

    NXPTZ2 120Vac Full HD 30x wiper cable 3m
  • NXPTZHD12VW0Z00C

    NXPTZ2 230Vac Full HD 30x wiper cable 3m
  • MVXT2Q0SFZ01BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 336x256; 30Hz; cable tail 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2Q0SFZ01B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 336x256; 7.5Hz; cable tail 4m; sunshield; -50°C/+65°C. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2Q0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 336x256; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2Q0SAZ00B

    MVXT with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; IP H264/AVC version; thermal camera 9mm; 336x256; 7.5Hz; armoured cable 4m (13 ft); sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SFZ01BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 30Hz; cable tail 4m; sunshield; ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SFZ01B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 7.5Hz; cable tail 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 9mm; 640x512; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2H0SAZ00B

    MVXT with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; IP H264/AVC version; thermal camera 9mm; 640x512; 7.5Hz; armoured cable 4m (13 ft); sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SFZ01BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 30Hz; cable tail 4m; sunshield; ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SFZ01B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 7.5Hz; cable tail 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -50°C ≤ Ta ≤ +65°C; IP66/68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/IP68. ETL listed for USA Class I Zone 1 AEx db IIC T5 Gb; Zone 21 AEx tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. ETL listed for Canada Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -50°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SAZ00BH

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 30Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MVXT2D0SAZ00B

    MVXT thermal camera with radiometric functions; in AISI 316L; 12-24Vdc/24Vac; version IP H264/AVC; 35mm; 640x512; 7.5Hz; armoured cable 4m; sunshield. ATEX Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. IECEx Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68. EAC Ex 1Ex db IIC T5 Gb X; Ex tb IIIC T100°C Db X; -60°C ≤ Ta ≤ +65°C; IP66/IP68. INMETRO Ex db IIC T5 Gb; Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/IP68. UK Ex Ex II 2G Ex db IIC T5 Gb; Ex II 2D Ex tb IIIC T100°C Db; -60°C ≤ Ta ≤ +65°C; IP66/68.
  • MBX1MAA

    MBX1MAA

    Explosion-proof communication box in AISI 316L stainless steel; IN 230Vac OUT 24Vac. ATEX Ex II 2G Ex db IIC T6...T5 Gb; Ex II 2D Ex tb IIIC T85°C...T100°C Db; -40°C ≤ Ta ≤ +60°C or +70°C. IECEx Ex db IIC T6...T5 Gb; Ex tb IIIC T85°C...T100°C Db; -40°C ≤ Ta ≤ +60°C or +70°C. EAC Ex 1Ex db IIC T6...T5 Gb X; Ex tb IIIC T85°C...T100°C Db X; -40°C ≤ Ta ≤ +60°C or +70°C. INMETRO Ex db IIC T6...T5 Gb; Ex tb IIIC T85°C...T100°C Db;-40°C ≤ Ta ≤ +60°C or +70°C. KCs Ex d IIC T6...T5; Ex tb IIIC T85°C...T100°C; ;-40°C ≤ Ta ≤ +60°C or +70°C. UL listed for USA Class I; Zone 1; AEx db IIC T6...T5 Gb; Zone 21; AEx tb IIIC T85°C...T100°C Db; -40°C ≤ Ta ≤ +60°C or +70°C. UL listed for Canada Ex db IIC T6...T5 Gb X Ex tb IIIC T85°C...T100°C Db X; -40°C ≤ Ta ≤ +60°C or +70°C. UK Ex Ex II 2G Ex db IIC T6...T5 Gb; Ex II 2D Ex tb IIIC T85°C...T100°C Db; -40°C ≤ Ta ≤ +60°C or +70°C.