Colección: Productos

6526 Productos

  • AC-LSP-EPLT-1M

    LifeSafety Power - FLEXPOWER EPLT-1M - Mercury Expansion Plate for MCLASS- Mercury/LSP board addition.
  • AC-LSP-F8

    The F8 module provides 8 protected outputs; each output programmable to enable voltage on activation of the fire alarm interface (FAI); disable voltage on FAI or provide a constant output voltage ATM style fuse: 3A/per output
  • AC-LSP-F8P

    The F8P module provides 8 protected outputs; each output programmable to enable voltage on activation of the fire alarm interface (FAI); disable voltage on FAI or provide a constant output voltage Solid state circuit breaker: 2.5A/per output Class 2 power limited
  • AC-LSP-FPO150

    150W-12/24VDC PS; Backplate; Standoffs; & E4M size cabinet kit: The FlexPower AC-LSP-FPO150 (FPO150-2D8E4M1) is an offline switchmode power supply battery charger system. The unit is user selectable for 12 or 24VDC. Providing two independent outputs; the first output provides continuous output power for system use and the second is programmable for either fail-safe or fail-secure operation; activated when the fire alarm disconnect is initiated. Also providing 16 auxiliary power distributed outputs; the unit has provisions for mounting a variety of Mercury boards in the cabinet proper (E4M) and cabinet door (EM1). The unit is configured in painted; steel; locking enclosure with tamper switch and integral battery space. Size: 20" x 24" x 4.5"; Weight: 21 lb. (LifeSafety Power Part Number: FPO150-2D8E4M1)
  • AC-LSP-FPO150-8DR-DV

    8 Door Access/Dual Voltage 150W PS/C ;12VDC@4A and 24VDC@4A System Features: One battery set supports all voltages; microprocessor battery charging; 80Ah charge capability; continuous and switched DC outputs; eight 12 or 24VDC auxiliary outputs fused at 3A (Class 2 power limited version also available); fire alarm input (FAI); eight opto isolated; NO/NC; access control inputs; eight relay lock control outputs; programmable for either 12 or 24VDC; failsafe or failsecure; and FAI; fault detection reporting with delay; system can be web-managed (w/ NetLink module); 120V/230VAC; locking enclosure: 16" X 20" X 4.5"; ten year warranty; US/Canada agency listed for access; security; fire; CCTV; mass notification (LifeSafety Power Part Number: FPO150-B100C8D8E2)
  • AC-LSP-FPO150-8DR-SV

    8 Door Access/Single Voltage 150W PS/C ; 12VDC@12A or 24VDC@6A System Features: 80Ah charge capability; microprocessor battery charging; charger software algorithm minimizes effects of deep battery discharge; continuous and switched DC outputs; eight 12 or 24VDC auxiliary outputs fused at 3A (Class 2 power limited version also available); fire alarm input (FAI); eight opto isolated; NO/NC; access control inputs; eight relay lock control outputs; programmable for either 12 or 24VDC; failsafe or failsecure; and FAI; fault detection reporting with delay; system can be web-managed (w/ NetLink module); 120V/230VAC; locking enclosure: 16" X 20" X 4.5"; ten year warranty; US/Canada agency listed for access; security; fire; CCTV; mass notification (LifeSafety Power Part Number: FPO150-C8D8E2)
  • AC-LSP-FPO150-B1002D8PM8NL4E4M/T8-C

    LifeSafety Power; Mercury 8DR; ProWire; Tie Wrap Cable Management; Networked; 170W dual voltage; 120/230VAC Input access power system.
  • AC-LSP-FPO150-B100C82D8PE4M-T8-A

    150W power supply; 12A/12V or 6A/24V|12V secondary voltage power module. Adjustable 5-18V output @ 4A max; class 2 power limited|8 relay lock control outputs fused at 3A per output; each output selectable for FAI; failsafe; failsecure|16 DC auxiliary outputs class 2 power limited at 2.5A per output; each output selectable for Bus1 or Bus2|E4 enclosure size 24H x 20W x 4.5D with Mercury back plate; Prewired; Tiewrap; 8 doors; Mercury MR52 / LP1502 board(s) (LifeSafety Power Part Number: FPO150-B100C82D8PE4M/T8-A)
  • AC-LSP-FPO150-B100C8D8NL4E4M

    150W Dual Voltage; 120 VAC Input; AC Fault System Fault form C contacts may be triggered by low/no battery; 8 Lock Outputs/8 Auxiliary Outputs. Backplate mounting for LP1502; LP4502; LP2500; MR52; MR16IN; E4M Enclosure Size: 24H x 20W x 6.5D in (LifeSafety Power Part Number: FPO150-B100C8D8NL4E4M)
  • AC-LSP-FPO150-B100C8P2D8PE4M-T8-A

    LifeSafety Power AC-LSP-FPO150-B100C8P2D8PE4M-T8-A ; Mercury ProWire Power Systems; 150W Dual Voltage; 120 VAC; 8 Lock Outputs / 16 Auxiliary Outputs; Size: 24.0H x 20.0W x 6.5D in (60.96 x 50.8 x 16.51 cm); 8 Doors; TieWrap; Prewired for one LP1502 and three MR52 boards; 31.50 lbs (14.29kg)
  • AC-LSP-FPO150-B100D8PM8NL4E4M

    Power supply board 150W; 12A/12V or 6A/24V | Secondary voltage power supply; 5-18V adjustable @ 4A max; class 2 power limited output | 8 auxiliary DC outputs class 2 power limited at 2.5A per output | Eight output smart distribution module; fused at 3A per output | Four port network monitoring module | Enclosure; Size 24. (20W x 24H x 4.5D) with backplate which can hold up to four Mercury boards. Battery space available in front of Mercury boards.
  • AC-LSP-FPO150-B100D8PM8NL4E6M

    Power supply board 150W; 4A/12V or 4A/24V | Secondary voltage power supply; 5-18V adjustable @ 4A max; class 2 power limited output | Eight output smart distribution module; fused at 3A per output | Four port network monitoring module | Enclosure; Size 30W x 23H x 6.5D with Mercury backplate (Lifesafety Power Part #: FPO150-B100D8PM8NL4E6M)
  • AC-LSP-FPO150-PS

    The FPO150 150W Power Supply Board is a high efficiency; off-line switchmode power supply-battery charger designed as a general purpose power supply to provide uninterrupted power for locks; auxiliary equipment and access controllers. Capable of providing two power outputs and featuring user selectability for 12 or 24 VDC; the unit provides multiple outputs; fire alarm interface; AC fault reporting; system faultreporting; form ‘C’ fault relay contacts and a host of features and functions designed to support the access control industry.(LifeSafety Power Part Number: FPO150)
  • AC-LSP-FPO150/150-16DR-DV

    16 Door Access/Dual Voltage 300W PS/C; 12VDC@12A and 24VDC@6A System Features: 80Ah charge capability; microprocessor battery charging; charger software algorithm minimizes effects of deep battery discharge; continuous and switched DC outputs; sixteen 12 or 24VDC auxiliary outputs fused at 3A (Class 2 power limited version also available); fire alarm input (FAI); sixteen opto isolated; NO/NC; access control inputs; sixteen relay lock control outputs; programmable for either 12 or 24VDC; failsafe or failsecure; and FAI; fault detection reporting with delay; system can be web-managed (w/ NetLink module); 120V/230VAC; locking enclosure; 20" X 24" X 4.5"; ten year warranty; US/Canada agency listed for access; security; fire; CCTV; mass notification (LifeSafety Power Part Number: FPO150/150-2C82D8E4)
  • AC-LSP-FPO150/250-2D82M8NL4E6M1

    LifeSafety Power Mercury Unified Unified Power Systems; 400W Dual Voltage; 120 VAC; 16 Managed / 16 Auxiliary Outputs
  • AC-LSP-FPO150/250-2D8P2M8NL4E4M1

    Power supply board 150W; 12A/12V or 6A/24V | Power supply board 250W; 20A/12V or 10A/24V | 16 auxiliary DC outputs class 2 power limited at 2.5A per output | Eight output smart distribution module; fused at 3A per output | Eight output smart distribution module; fused at 3A per output | Four port network monitoring module | Enclosure 20W x 24H x 4.5D with backplate and door mount which can hold up to eight Mercury boards. Requires separate enclosure for batteries.
  • AC-LSP-FPO150/250-2D8P2M8NL4E6M1

    Power supply board 150W; 12A/12V or 6A/24V | Power supply board 250W; 20A/12V or 10A/24V | 16 auxiliary DC outputs class 2 power limited at 2.5A per output | Eight output smart distribution module; fused at 3A per output | Eight output smart distribution module; fused at 3A per output | Four port network monitoring module | Enclosure 30W x 23H x 6.5D with Mercury backplate and door mount option (Lifesafety Power Part #: FPO150/250-2D8P2M8NL4E6M1)
  • AC-LSP-FPO150/250-2D8P2M8NL4E8M2

    Power supply board 150W; 12A/12V or 6A/24V | Power supply board 250W; 20A/12V or 10A/24V | 16 auxiliary DC outputs class 2 power limited at 2.5A per output | 16 output smart distribution module; fused at 3A per output | Four port network monitoring module | Enclosure 30W x 36H x 4.5D with backplate which can hold up to eight Mercury boards. Battery space available.
  • AC-LSP-FPO150/250-3D8P2M8NL4E4M1/T16-A

    LifeSafety Power; Mercury 16DR; ProWire; Tie Wrap Cable Management; Networked; 452W dual voltage; 120/230VAC Input access power system.
  • AC-LSP-FPO150/250-3D8P2M8NL4E4M1/T16-C

    LifeSafety Power; Mercury 16DR; ProWire; Tie Wrap Cable Management; Networked; 452W dual voltage; 120/230VAC Input access power system.
  • AC-LSP-FPO150/250-3D8P2M8NL4E8M2/P16-B

    LifeSafety Power ProWire 16 Door Panduit Unified Power wall mount dual voltage access power system; precision wired for MERCURY controllers (sold seperately). ProWire enables the specification and installation of standardized access power equipment across an enterprise for uniform operation; maintenance and servicing.
  • AC-LSP-FPO150–B100-2D8PM8NL4E4M1-P8-A

    150W power supply; 12A/12V or 6A/24V|12V secondary voltage power module. Adjustable 5-18V output @ 4A max; class 2 power limited|16 DC auxiliary outputs class 2 power limited at 2.5A per output; each output selectable for Bus1 or Bus2|8 out managed distribution module; fused at 3A per output|Four port network monitoring module|E4 enclosure size 24H x 20W x 4.5D with Mercury back plate and door mount kit; Panduit; 8 Doors; Mercury LP1502/MR52 board(s)(LifeSafety Power AC-LSP-FPO150-B100C8P2D8PE4M-T8-A)
  • AC-LSP-FPO250

    The FPO250 250W Power Supply Board is a high efficiency; off-line switchmode power supply-battery charger designed as a general purpose power supply to provide uninterrupted power for locks; auxiliary equipment and access controllers. Capable of providing two power outputs and featuring user selectability for 12 or 24 VDC; the unit provides multiple outputs; fire alarm interface; AC fault reporting; system faultreporting; form ‘C’ fault relay contacts and a host of features and functions designed to support the access control industry.(LifeSafety Power Part Number: FPO250)
  • AC-LSP-FPO250-16DR-SV

    16 Door Access/Single Voltage 250W PS/C; 12VDC@20A or 24VDC@10A System Features: 80Ah charge capability; microprocessor battery charging; charger software algorithm minimizes effects of deep battery discharge; continuous and switched DC outputs; sixteen 12 or 24VDC auxiliary outputs fused at 3A (Class 2 power limited version also available); fire alarm input (FAI); sixteen opto isolated; NO/NC; access control inputs; sixteen relay lock control outputs; programmable for either 12 or 24VDC; failsafe or failsecure; and FAI; fault detection reporting with delay; system can be web-managed (w/ NetLink module); 120V/230VAC; locking enclosure; 20" X 24" X 4.5"; ten year warranty; US/Canada agency listed for access; security; fire; CCTV; mass notification (LifeSafety Power Part Number: FPO250-2C82D8E4)